Draft synthesis: Human evidence for BPC-157 — submissions
The 4 submissions received, published in full with declared interests and secretariat responses.
§2Submissions and responses
4 submissions were received. Each is published in full below with its declared interest, the secretariat response and the disposition. The Institute publishes submissions it did not accept in the same form as those it did.
Efficacy outcomes are rated for certainty and harms are not
The draft assigns certainty ratings to the efficacy outcomes and reports harms narratively without ratings. The respondent states that the asymmetry implies harms are less amenable to assessment when they are simply less well measured.
The respondent proposes that harms carry certainty ratings on the same scale, with the reasons for downgrading stated.
The secretariat accepts this submission. Rating one side of the balance and not the other produces a document that cannot be used to weigh them.
Every reported harm now carries a certainty rating on the same scale as the efficacy outcomes, with the downgrade reasons stated, and discontinuation for adverse events appears in the summary of findings rather than in an annex.
The same concept is given three different names in one document
The draft refers to the same quantity as a response rate, a responder proportion and a categorical outcome in different sections. The respondent, who works in health-technology assessment, states that a reader cannot tell whether the three refer to one thing or to three.
The respondent proposes that the glossary term be used at every occurrence and that the glossary entry be linked at first use in each section rather than only at first use in the document.
The secretariat accepts this submission. The variation was stylistic and its cost to the reader exceeds any benefit.
A single term is now used throughout for each defined concept, and the glossary entry is linked at first use within each section rather than once per document.
The search date is not on the face of the document
The draft carries a publication date and a review date but not the date on which the evidence was last searched. Those are three different dates and only the third tells a reader how current the assessment is. A document published in one quarter may rest on a search run two quarters earlier, and nothing on the page allows that gap to be measured.
The respondent proposes that the search date be printed adjacent to every certainty rating rather than in the methods section, on the ground that a reader who acts on a rating is unlikely to have read the methods section first.
The secretariat accepts this submission. The distinction between publication, review and search dates is real and the draft did not make it visible where it mattered.
The search date is now printed adjacent to every certainty rating and is carried in the document metadata, so that the interval between the search and the reading is visible without reference to the methods section.
Studies not published in English were excluded without assessment
The respondent states that a language restriction was applied at screening and that for some of the compounds in scope a substantial literature is published in other languages.
The respondent proposes that the restriction be removed and the review re-run.
The secretariat accepts this submission in part. The restriction is removed prospectively and the records already excluded on language grounds have been retrieved and screened on title and abstract in translation. The full re-run proposed is not undertaken, and the limitation is recorded rather than concealed.
Language restriction is removed from the protocol for the series, the records previously excluded on that ground are listed with their screening outcome, and the residual limitation is stated in the abstract of this review.
References cited on this page
References are numbered in order of first citation in this document. Each superscript in the text links to its entry below.
- International Organization for Standardization. ISO/IEC 17025:2017 General Requirements for the Competence of Testing and Calibration Laboratories. ISO/IEC Standard 2017;3rd edition. identifier not held by the Institute
Identifiers are reproduced only where the Institute holds them. Where a digital object identifier or PubMed identifier is not shown, the Institute has recorded the journal and year and has not constructed an identifier.