CEI-MS-15 — worked example

A worked calculation, and an illustrative mass balance showing what a purity figure alone does not establish.

Document identifier
CEI-MS-15/6
Series
Methodological standard
Version
2.0
Published
12 May 2023
Last reviewed
12 Jul 2024
Next review
12 Jul 2027
Identifier
10.71829/cei.meth.14
Certainty
High
Cycle
2023 Q2
Category
Documentation

§6Worked example

§6.1Worked example — why report-to-batch matching decides what a report can support

  1. A supplier publishes 388 third-party reports. An assessor samples 60 and attempts to match each to a batch code on material obtained through the ordinary supply route.
  2. 41 of 60 match a specific batch. 19 carry either no batch code or a code that does not correspond to any code observed on a container.
  3. The 41 matched reports support statements about the batches they name. Each is a data point about a specific quantity of material.
  4. The 19 unmatched reports support a different and much weaker statement: that testing occurred. They cannot support any claim about material a purchaser receives, because there is no way to establish whether the material tested and the material received have any relationship.
  5. Extrapolating from 388 reports to "this supplier’s material is tested" therefore requires an assumption the reports themselves do not license. The Institute records the matched count and the unmatched count separately for this reason, and places only the matched reports in the verified column.

§6.2Illustrative mass balance

References cited on this page

References are numbered in order of first citation in this document. Each superscript in the text links to its entry below.

  1. International Organization for Standardization. ISO/IEC 17025:2017 General Requirements for the Competence of Testing and Calibration Laboratories. ISO/IEC Standard 2017;3rd edition. identifier not held by the Institute
  2. United States Pharmacopeial Convention. General Chapter ⟨1225⟩ Validation of Compendial Procedures. United States Pharmacopeia — National Formulary (USP–NF) 2024;USP 2024 Issue 1. identifier not held by the Institute

Identifiers are reproduced only where the Institute holds them. Where a digital object identifier or PubMed identifier is not shown, the Institute has recorded the journal and year and has not constructed an identifier.

Nothing published by the Institute is medical advice, a diagnosis, a prescription, a treatment recommendation or a purchasing recommendation. Compounds supplied for research use are not approved for human or veterinary use in any jurisdiction, and a favourable analytical assessment of a supplier is not a statement that any product is safe or effective. The Institute publishes certainty ratings and never recommendations. No telephone number, messaging handle or ordering channel appears anywhere on this site.